Título: | Stability of a Novel Intraocular Lens Design: Comparison of Two Trifocal Lenses |
Autores: | Poyales Galán, Francisco ; Garzón Jiménez, Nuria ; Rozema, Jos J. ; Romero Royo, Concepción ; Ortíz de Zárate, Begoña |
Tipo de documento: | texto impreso |
Editorial: | Slack Incorporated, 2016-06-17 |
Dimensiones: | application/pdf |
Nota general: | info:eu-repo/semantics/openAccess |
Idiomas: | |
Palabras clave: | Estado = Publicado , Materia = Ciencias Biomédicas: Medicina: Oftalmología , Materia = Ciencias Biomédicas: Óptica y optometría: Lentes de contacto , Materia = Ciencias Biomédicas: Óptica y optometría: Optometría , Materia = Ciencias Biomédicas: Óptica y optometría: Óptica oftálmica , Tipo = Artículo |
Resumen: |
PURPOSE: To compare visual outcomes, rotational stability, and centration in a randomized controlled trial in patients undergoing cataract surgery who were bilaterally implanted with two different trifocal intraocular lenses (IOLs) with a similar optical zone but different haptic shape. METHODS: Twenty-one patients (42 eyes) with cataract and less than 1.50 D of corneal astigmatism underwent implantation of one FineVision/MicoF IOL in one eye and one POD FineVision IOL in the contralateral eye (PhysIOL, Liège, Belgium) at IOA Madrid Innova Ocular, Madrid, Spain. IOL allocation was random. Outcome measures, all evaluated 3 months postoperatively, included monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), distance-corrected intermediate (DCIVA), and near (DCNVA) visual acuity (at 80, 40, and 25 cm) under photopic conditions, refraction, IOL centration, haptic rotation, dysphotopsia, objective quality of vision and aberration quantification, patient satisfaction, and spectacle independence. RESULTS: Three months postoperatively, mean monocular UDVA, CDVA, DCIVA, and DCNVA (40 cm) under photopic conditions were 0.04 ± 0.07, 0.01 ± 0.04, 0.15 ± 0.11, and 0.16 ± 0.08 logMAR for the eyes implanted with the POD FineVision IOL and 0.03 ± 0.05, 0.01 ± 0.02, 0.17 ± 0.12, and 0.14 ± 0.08 logMAR for those receiving the FineVision/MicroF IOL. Moreover, the POD FineVision IOL showed similar centration (P > .05) and better rotational stability (P CONCLUSIONS: This study revealed similar visual outcomes for both trifocal IOLs under test (POD FineVision and FineVision/MicroF). However, the POD FineVision IOL showed better rotational stability, as afforded by its design. |
En línea: | https://eprints.ucm.es/38290/1/stability%20of%20a%20novel_2016-Web.pdf |
Ejemplares
Estado |
---|
ningún ejemplar |