Título: | In vivo subjective and objective longitudinal chromatic aberration after bilateral implantation of the same design of hydrophobic and hydrophilicintraocular lenses |
Autores: | Viñas Peña, María ; Dorronsoro Díaz, Carlos ; Garzón Jiménez, Nuria ; Poyales, Francisco ; Marcos Celestino, Susana |
Tipo de documento: | texto impreso |
Editorial: | Elsevier, 2015-10 |
Dimensiones: | application/pdf |
Nota general: | info:eu-repo/semantics/openAccess |
Idiomas: | |
Palabras clave: | Estado = Publicado , Materia = Ciencias: Física: Optica , Materia = Ciencias Biomédicas: Óptica y optometría: Lentes de contacto , Materia = Ciencias Biomédicas: Óptica y optometría: Optometría , Materia = Ciencias Biomédicas: Óptica y optometría: Materiales ópticos , Tipo = Artículo |
Resumen: |
PURPOSE: To measure the longitudinal chromatic aberration invivo using psychophysical and wavefront-sensing methods in patients with bilateral implantation of monofocal intraocular lenses (IOLs) of similar aspheric design but different materials (hydrophobic Podeye and hydrophilic Poday). SETTING: Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain. DESIGN: Prospective observational study. METHODS: Measurements were performed with the use of psychophysical (480 to 700 nm) and wavefront-sensing (480 to 950 nm) methods using a custom-developed adaptive optics system. Chromatic difference-of-focus curves were obtained from best-focus data at each wavelength, and the longitudinal chromatic aberration was obtained from the slope of linear regressions to those curves. RESULTS: The longitudinal chromatic aberration from psychophysical measurements was 1.37 diopters (D) ± 0.08 (SD) (hydrophobic) and 1.21 ± 0.08 D (hydrophilic). From wavefront-sensing, the longitudinal chromatic aberration was 0.88 ± 0.07 D and 0.73 ± 0.09 D, respectively. At 480 to 950 nm, the longitudinal chromatic aberration was 1.27 ± 0.09 D (hydrophobic) and 1.02 ± 0.13 D (hydrophilic). The longitudinal chromatic aberration was consistently higher in eyes with the hydrophobic IOL than in eyes with the hydrophilic IOL (a difference of 0.16 D and 0.15 D, respectively). Similar to findings in young phakic eyes, the longitudinal chromatic aberration from the psychophysical method was consistently higher than from wavefront-sensing, by 0.48 D (35.41%) for the hydrophobic IOL and 0.48 D (39.43%) for the hydrophilic IOL. CONCLUSION: Longitudinal chromatic aberrations were smaller with hydrophilic IOLs than with hydrophobic IOLs of the same design. |
En línea: | https://eprints.ucm.es/34976/1/2016-In%20vivo%20EPRINTS.pdf |
Ejemplares
Estado |
---|
ningún ejemplar |