Título:
|
Rad-Tol Pt-100 isolation amplifiers for the LHC cryogenic system
|
Autores:
|
Agapito Serrano, Juan Andrés ;
Casas-Cubillos, Juan ;
Fernandes, Ana C. ;
Franco Peláez, Francisco Javier ;
Gonçalves, Isabel ;
Hernández Cachero, Antonio ;
Marques, José G. ;
Rodríguez-Ruiz, Miguel Ángel ;
Zong, Yi
|
Tipo de documento:
|
texto impreso
|
Editorial:
|
CERN Publishing Service, 2004-08-13
|
Dimensiones:
|
application/pdf
|
Nota general:
|
cc_by
info:eu-repo/semantics/openAccess
|
Idiomas:
|
|
Palabras clave:
|
Estado = Publicado
,
Materia = Ciencias: Física: Electrónica
,
Materia = Ciencias: Física: Radiactividad
,
Tipo = Sección de libro
|
Resumen:
|
The cryogenic system of the LHC will use Pt-100 sensors to measure temperatures between 40-300K and isolation devices will be used. The selected commercial components must be rad-tolerant since a total radiation dose of 5E12 n/cm2 &100 Gy is expected during ten years of the LHC lifetime. Neutron tests in this family of devices were performed and the results are shown in this paper.
|
En línea:
|
https://eprints.ucm.es/id/eprint/29016/1/LECC2004-Agapito.pdf
|